Home › Gas detectors and meters › Fixed systems & control panels › Dräger Polytron® 6100 EC WL — wireless fixed detector for toxic gases and oxygen
← Back to: Fixed systems & control panels
Dräger Polytron® 6100 EC WL — wireless fixed detector for toxic gases and oxygen — Fixed systems & control panels | SafeTech

Dräger Polytron® 6100 EC WL — wireless fixed detector for toxic gases and oxygen

The Dräger Polytron® 6100 EC WL is a wireless, intrinsically safe electrochemical transmitter for continuous monitoring of toxic gas and oxygen concentrations. It transmits readings wirelessly (ISA100 Wireless™ or WirelessHART®) and is battery-powered, providing up to 24 months of continuous operation — a flexible, cost-effective solution for expanding and upgrading installations as well as for new projects where cabling is too costly or technically difficult. SIL2-compliant, it detects more than 140 gases thanks to proven DrägerSensor units, with signal transmission over distances of up to 500 m.

The Dräger Polytron® 6100 EC WL is a wireless, intrinsically safe electrochemical transmitter for continuous monitoring of toxic gas and oxygen concentrations. It transmits readings wirelessly (ISA100 Wireless™ or WirelessHART®) and is battery-powered, providing up to 24 months of continuous operation — a flexible, cost-effective solution for expanding and upgrading installations as well as for new projects where cabling is too costly or technically difficult. SIL2-compliant, it detects more than 140 gases thanks to proven DrägerSensor units, with signal transmission over distances of up to 500 m.

Note: The sensor variant, range and gas are matched to the application and area. The radio standard (ISA100/WirelessHART), sensor selection, configuration and calibration are carried out as part of the deployment.

Key features

  • Wireless transmitter for continuous monitoring of toxic gases and oxygen.
  • Battery-powered — up to 24 months of continuous operation (optional 24 V supply).
  • Selectable radio standards: ISA100 Wireless™ or WirelessHART®.
  • Intrinsically safe, SIL2-compliant (IEC 61508) — maintenance in the Ex zone.
  • Proven DrägerSensor EC sensors — over 140 gases, factory calibration.
  • Signal transmission up to 500 m; access via Bluetooth® (PolySoft).
  • Stainless steel enclosure, IP66/67; range −40°C to +65°C.

Technical specification

ParameterValue
Typewireless fixed transmitter (Ex)
Measuring principleelectrochemical (DrägerSensor EC)
CommunicationISA100 Wireless™ or WirelessHART®; range up to 500 m; Bluetooth® (PolySoft)
Power supplylithium-thionyl chloride battery (up to 24 months); optionally 24 V
Measured gasestoxic gases and oxygen — over 140 substances
Safetyintrinsically safe; SIL2 (IEC 61508) — optional
Operating temperature−40°C to +65°C
Enclosure / IPstainless steel; IP66/67
Dimensions / weight32 × 15 × 17 cm / 3.2 kg
ApprovalsATEX, IECEx, CE, GOST (EAC), MED; UL/CSA — optional
ManufacturerDräger

Applications

Expansion and modernisation of installations without cabling, loading and inspection zones, hard-to-reach locations or areas without infrastructure, industrial plants — cost-effective wireless monitoring of toxic gases and oxygen.

Frequently asked questions (FAQ)

What sets the Polytron 6100 EC WL apart?

It is the wireless version — it transmits readings by radio (ISA100 or WirelessHART) and runs on a battery for up to 24 months, so it requires no cabling or mains power.

How far does it transmit the signal?

Up to 500 m; with a repeater function the range can be extended and redundant communication paths can be built.

Does it meet functional safety requirements?

Yes — in the ISA100 standard with the PROFIsafe protocol the device meets SIL2-level requirements.

Brand and service

Dräger — SafeTech: selection, delivery, design, installation, calibration and servicing of Dräger fixed gas detection systems.

Why SafeTech

  • 23 years of experience in gas detection (in business since 2003).
  • Authorised distributor and authorised service station (Honeywell, Bieler+Lang).
  • In-house service, calibration, certification and adjustment in Suchy Dwór near Gdynia — nationwide service across Poland.
  • Training and technical support (SafeTech Safety Academy).

Availability and service — Gdynia and the Tri-City

Dräger Polytron® 6100 EC WL — wireless fixed detector for toxic gases and oxygen — sales, selection, calibration and servicing in Gdynia (Suchy Dwór, on the border of Gdynia and the Kosakowo municipality). We serve the Tri-City (Gdańsk, Sopot, Gdynia), Rumia, Reda, Wejherowo, the Pomeranian Voivodeship and all of Poland. Ask about our offer and availability.

Type at least 2 characters — e.g. x-am, Dräger