Gas detection3
Respiratory protection4
Technical rescue9
Firefighting4
Safety & environment4
Personal protective equipment2

Dräger X-pid® 9000 / 9500 — selective VOC detector (benzene, PID + GC)
The Dräger X-pid 9000/9500 is a portable, selective detector for volatile organic compounds that combines gas chromatography (pre-separation) with photoionization detection (PID 10.6 eV). This lets it measure specific compounds — primarily the carcinogen benzene and 1,3-butadiene — while eliminating interference from other hydrocarbons. The 9500 version quantifies around 40 compounds (incl. benzene, butadiene, toluene, xylenes, vinyl chloride, ethylene oxide), and the 9500+ detects benzene down to 5 ppb. It operates without consumables (no tubes), and is controlled via an intrinsically safe smartphone with an app.
The Dräger X-pid 9000/9500 is a portable, selective detector of volatile organic compounds that combines gas chromatography (pre-separation) with photoionization detection (PID 10.6 eV). This allows it to measure specific compounds — primarily carcinogenic benzene and 1,3-butadiene — eliminating interference from other hydrocarbons. The 9500 version quantifies about 40 compounds (including benzene, butadiene, toluene, xylenes, vinyl chloride, ethylene oxide), and the 9500+ detects benzene from as low as 5 ppb. It operates without consumables (no tubes), and is controlled via an intrinsically safe smartphone with a dedicated app.
Note: The X-pid 9000 is limited to benzene and 1,3-butadiene; the 9500 covers ~40 compounds; the 9500+ is the same hardware with an improved calculation model (benzene from 5 ppb). We help select the right version for your application.
Key features
- Selective VOC measurement after pre-separation (GC) — eliminates interference from other hydrocarbons.
- 9000: benzene and 1,3-butadiene; 9500: ~40 compounds quantified.
- Benzene detection limit from 50 ppb (9000/9500), from 5 ppb (9500+).
- Two modes: „Seeker” (total VOC, direct reading) and „Analysis” (selective, benzene ~30 s).
- No consumables per measurement (no indicator tubes).
- Integrated pump with probe; operated via an intrinsically safe smartphone (app).
- GasVision 8 software; IP54 protection rating of the sensor unit.
Technical specifications
| Parameter | Value |
|---|---|
| Type | portable selective VOC detector (GC + PID 10.6 eV) |
| Measured compounds | 9000: benzene, 1,3-butadiene · 9500: ~40 compounds (benzene, butadiene, toluene, xylenes, VC, ETO and others) |
| Detection limit | benzene from 50 ppb (9000/9500), from 5 ppb (9500+); range up to 25 ppm |
| Operating modes | Seeker (total VOC, up to 40 ppm) and Analysis (selective, benzene ~30 s) |
| Sampling | integrated pump with probe/hose |
| Power / operating time | approx. 8 h of sensor unit operation; controlled by intrinsically safe smartphone |
| Dimensions / weight | approx. 132 × 281 × 56 mm / ~880 g (sensor unit) |
| Protection rating | IP54 |
| Approvals | ATEX/IECEx Ex ia IIC T4 Ga; Class I Div 1/Zone 0; −10…+35°C |
| Software | mobile app + GasVision 8 (Windows) |
Applications
Petrochemicals and refineries, monitoring of benzene and carcinogenic substances, TWA measurements in the ppb–ppm range, explosion-hazard zones, occupational hygiene.
Frequently asked questions (FAQ)
What does the Dräger X-pid measure?
It selectively measures specific volatile organic compounds — primarily benzene and 1,3-butadiene. Thanks to pre-separation (GC), the reading is not distorted by other hydrocarbons.
How does the 9500 differ from the 9000?
The 9000 measures only benzene and 1,3-butadiene; the 9500 quantifies about 40 compounds. The 9500+ variant detects benzene from as low as 5 ppb.
Are tubes or consumables required?
No — the X-pid performs measurements without indicator tubes. It is operated via an intrinsically safe smartphone with an app.
Brand & service
Dräger — available from SafeTech together with expert configuration selection, calibration and service.
Why SafeTech
- 23 years of experience in gas detection (in business since 2003).
- Distribution and support for the Dräger brand; sensor configuration selection for your application.
- In-house service, calibration, certification and adjustment in Suchy Dwór near Gdynia — service across Poland.
- Training and technical support (SafeTech Safety Academy).
Availability & service — Gdynia and Tricity
Dräger X-pid® 9000 / 9500 — selective VOC detector (benzene, PID + GC) — sales, selection, calibration and service in Gdynia (Suchy Dwór, on the border of Gdynia and the Kosakowo municipality). We serve the Tricity (Gdańsk, Sopot, Gdynia), Rumia, Reda, Wejherowo, the Pomerania region and all of Poland. Ask about a quote and availability.
Accessories and compatible equipment
- Calibration & bump test: stacja Dräger X-dock, calibration gas mixtures, regulators and pressure-reducing valves for cylinders.
- Sensors & filters: replacement sensors matched to the measured gas, dust and hydrophobic filters.
- Sampling: probe, hose, aspirator bulb (for diffusion versions).
- Carrying & protection: lanyard, clip, holder, transport case, charger/power supply.
Full selection of accessories and parts for this model — request a quote.