MSA ALTAIR 4XR — multi-gas detector (4-gas)
The MSA ALTAIR 4XR is a rugged 4-gas detector measuring combustible gases (LEL), oxygen (O₂), carbon monoxide (CO) and hydrogen sulphide (H₂S) using fast MSA XCell sensors. It responds to gas twice as fast as the market average and performs bump tests and calibration with half the calibration-gas consumption. Extremely durable: it survives drops and carries an IP68 rating. It performs well in confined spaces and field work. SafeTech provides selection, calibration and service.
The MSA ALTAIR 4XR is a rugged 4-gas detector measuring combustible gases (LEL), oxygen (O₂), carbon monoxide (CO) and hydrogen sulphide (H₂S) using fast MSA XCell sensors. It responds to gas twice as fast as the market average and performs bump tests and calibration with half the calibration-gas consumption. Extremely durable: it survives drops and carries an IP68 rating. It performs well in confined spaces and field work. SafeTech provides selection, calibration and service.
Key features
- Measurement of 4 gases: LEL, O₂, CO, H₂S with MSA XCell sensors.
- Gas response ~2× faster than the market average; bump/calibration at ½ gas consumption.
- IP68 rating (dust- and water-tight, 2 m for min. 1 h).
- Drop resistance: 25 drops from 1.2 m (MIL-STD-810G) and an incidental drop from 7.5 m.
- Runtime up to 24 h on a Li-Po battery.
- Temperature range −40 °C to +60 °C; 4-year warranty.
Technical specification
| Parameter | Value |
|---|---|
| Measured gases | LEL, O₂, CO, H₂S (XCell) |
| Ranges | CO 0–1999 ppm; H₂S 0–200 ppm; LEL 0–100%; O₂ 0–30% |
| Runtime | up to 24 h (Li-Po) |
| Protection rating | IP68 (2 m / min. 1 h) |
| Drop resistance | 25× from 1.2 m; incidental 7.5 m |
| Operating temperature | −40 °C to +60 °C |
| Warranty | 4 years |
| Alarms | visual, audible, vibrating |
Applications
Confined spaces (wells, tanks, sewers), fire services, industry, power generation, gas industry, water and wastewater utilities.
Frequently asked questions (FAQ)
Which gases does the ALTAIR 4XR measure?
Four simultaneously: combustible gases (LEL), oxygen (O₂), carbon monoxide (CO) and hydrogen sulphide (H₂S).
Is it suitable for confined spaces?
Yes — it is a classic 4-gas detector for confined-space entries; combined with a pump it enables measuring the atmosphere before entry.
How often should it be calibrated?
A bump test before use, full calibration usually every 6–12 months. We perform this at the SafeTech station in Gdynia.
Brand and service
MSA Safety — authorised sales, selection, calibration and service by SafeTech (Suchy Dwór near Gdynia).
Why SafeTech
- 23 years of experience in gas detection (the company has operated since 2003).
- Authorised distributor and authorised service station (including Honeywell, Dräger, GfG, MSA).
- In-house service, calibration, attestation and adjustment in Suchy Dwór near Gdynia — support throughout Poland.
- Training and technical support (SafeTech Safety Academy).
Availability and service — Gdynia and the Tricity
MSA ALTAIR 4XR — multi-gas detector (4-gas) — sales, selection, calibration and service in Gdynia (Suchy Dwór, on the border of Gdynia and the Kosakowo municipality). We serve the Tricity (Gdańsk, Sopot, Gdynia), Rumia, Reda, Wejherowo, the Pomeranian Voivodeship and all of Poland. Ask about our offer and availability.
Accessories and compatible equipment
- Calibration & bump test: stacja dokująca/kalibracyjna, calibration gas mixtures, regulators and pressure-reducing valves for cylinders.
- Sensors & filters: replacement sensors matched to the measured gas, dust and hydrophobic filters.
- Sampling: probe, hose, aspirator bulb (for diffusion versions).
- Carrying & protection: lanyard, clip, holder, transport case, charger/power supply.
Full selection of accessories and parts for this model — request a quote.