MSA Series 47K — fixed combustible gas and vapor detector
Series 47K is a fixed, catalytic combustible gas and vapor detector in a stainless-steel housing, available in a poison-resistant (PRP) version and a high-temperature (HT) version. A short response time, SIL 2 rating and a wide range of accessories make it an economical solution for protecting industrial installations.
Series 47K is a fixed, catalytic combustible gas and vapor detector in a stainless-steel housing, available in a poison-resistant (PRP) version and a high-temperature (HT) version. A short response time, SIL 2 rating and a wide range of accessories make it an economical solution for protecting industrial installations.
Key features
- Poison-resistant (PRP) and high-temperature (HT) versions — suited to demanding process conditions.
- 3-, 4- or 5-wire connection.
- Stainless-steel sensor housing — resistant to corrosion and mechanical damage.
- Full range of mounting accessories and weather covers.
- Short response time to combustible gas or vapor.
- Excellent performance-to-price ratio.
- SIL 2 safety integrity level.
Technical specification
| Parameter | Value |
|---|---|
| Type | catalytic combustible gas/vapor sensor |
| Versions | PRP (Poison Resistant), HT (High Temperature) |
| Electrical connection | 3-, 4- or 5-wire |
| Housing material | stainless steel |
| SIL level | SIL 2 |
| Example detected gases | acetic acid, acetone, acetylene, ammonia, butadiene, butane, methyl ethyl ketone, cyclohexane, diethyl ether, ethane, ethanol, ethylene, ethylene oxide, gasoline, hexane, hydrogen, methanol, pentane, propane and others |
Applications
Detecting leaks of combustible gases and vapors in industrial installations, refineries, chemical and process plants — wherever sensor resistance to poisoning and operation at elevated temperatures matter.
Frequently asked questions (FAQ)
What is the difference between the PRP and HT versions?
The PRP (Poison Resistant) version has increased sensor resistance to substances that poison the catalyst, while the HT (High Temperature) version is designed to operate at elevated process temperatures.
What wiring does Series 47K work with?
The sensor is available in 3-, 4- or 5-wire versions, allowing it to be matched to the existing installation and the type of control panel.
Does Series 47K meet SIL requirements?
Yes, the sensor has a SIL 2 safety integrity level, allowing it to be used in functional safety systems.
Brand and service
MSA Safety — authorized sales, selection, system design and service by SafeTech (Suchy Dwór near Gdynia).
Why SafeTech
- 23 years of experience in gas detection (the company has operated since 2003).
- Authorized distributor and authorized service station (including Honeywell, Dräger, GfG, MSA).
- In-house service, calibration, certification and adjustment in Suchy Dwór near Gdynia — service throughout Poland.
- Training and technical support (SafeTech Safety Academy).
Availability and service — Gdynia and the Tricity
Series 47K — fixed combustible gas and vapor detector — sales, selection, calibration and service in Gdynia (Suchy Dwór, on the border of Gdynia and the Kosakowo municipality). We serve the Tricity (Gdańsk, Sopot, Gdynia), Rumia, Reda, Wejherowo, the Pomeranian Voivodeship and all of Poland. Ask about a quote and availability.