HomeDetektory i mierniki gazuFixed systems & control panelsMSA ULTIMA X5000 — fixed gas detector (transmitter)
← Back to: Fixed systems & control panels
MSA ULTIMA X5000 — fixed gas detector (transmitter) — Fixed systems & control panels | SafeTech

MSA ULTIMA X5000 — fixed gas detector (transmitter)

The MSA ULTIMA X5000 is a modern fixed gas-detection transmitter for toxic, oxygen and combustible gases. Its standout feature is dual sensing — a single instrument supports two sensors, doubling measurement capability while reducing installation footprint. It offers 4–20 mA analog outputs with HART communication, an optional Bluetooth interface and broad certifications (ATEX, IECEx, DNV Marine, SIL 2). SafeTech designs, supplies and services fixed systems.

The MSA ULTIMA X5000 is a modern fixed gas-detection transmitter for toxic, oxygen and combustible gases. Its standout feature is dual sensing — a single instrument supports two sensors, doubling measurement capability while reducing installation footprint. It offers 4–20 mA analog outputs with HART communication, an optional Bluetooth interface and broad certifications (ATEX, IECEx, DNV Marine, SIL 2). SafeTech designs, supplies and services fixed systems.

Key features

  • Dual sensing — two sensors on a single transmitter.
  • Outputs: two 4–20 mA current sources, HART digital communication; optional Bluetooth (BLE).
  • XCell sensors and XIR PLUS infrared (combustible gases).
  • Wide operating temperature range −40 °C to +60 °C.
  • Certifications: CSA, ATEX, IECEx, Inmetro, DNV Marine, CE; suitable for SIL 2.
  • Power supply 11–30 VDC, < 5 W.

Technical specification

ParameterValue
Typefixed gas-detection transmitter
Sensorsdual sensing (2 sensors): XCell, XIR PLUS (IR)
Measured gasescombustible (0–100% LEL), CO, CO₂, H₂S, O₂ and others
Outputs2× 4–20 mA + HART; optional Bluetooth BLE
Power supply11–30 VDC, < 5 W
Operating temperature−40 °C to +60 °C
CertificationsATEX, IECEx, DNV Marine, CE, SIL 2
Weightapprox. 4 kg

Applications

Continuous monitoring of hazardous areas in industry, the gas sector, petrochemicals, power generation and marine facilities; integration with control panels and control systems.

Frequently asked questions (FAQ)

What does dual sensing mean on the X5000?

A single transmitter supports two sensors and generates two independent outputs — less installation and wiring for twice the number of measured points/gases.

Does the X5000 work with a control panel?

Yes — via 4–20 mA and HART it integrates with control panels and control systems; suitable for SIL 2 applications.

Does SafeTech design fixed systems?

Yes — we design, supply, install and service gas-detection systems throughout Poland.

Brand and service

MSA Safety — authorized sales, selection, system design and service by SafeTech (Suchy Dwór near Gdynia).

Why SafeTech

  • 23 years of experience in gas detection (the company has operated since 2003).
  • Authorized distributor and authorized service station (including Honeywell, Dräger, GfG, MSA).
  • In-house service, calibration, certification and adjustment in Suchy Dwór near Gdynia — service throughout Poland.
  • Training and technical support (SafeTech Safety Academy).

Availability and service — Gdynia and the Tricity

MSA ULTIMA X5000 — fixed gas detector (transmitter) — sales, selection, calibration and service in Gdynia (Suchy Dwór, on the border of Gdynia and the Kosakowo municipality). We serve the Tricity (Gdańsk, Sopot, Gdynia), Rumia, Reda, Wejherowo, the Pomeranian Voivodeship and all of Poland. Ask about a quote and availability.

Type at least 2 characters — e.g. x-am, Dräger