Gas detection3
Respiratory protection4
Technical rescue9
Firefighting4
Safety & environment4
Personal protective equipment2

WatchGas — calibration gases and sampling accessories
A full range of WatchGas reference (calibration) gases and sampling accessories: cylinders in sizes from 12 to 116 l (aluminium and steel), the low-adsorption, antistatic Last-O-More hose, ball floats (Ballfloat) protecting the hose from drawn-in liquid and dust, and a backpack for safe container sampling. Everything for bump testing, calibration and sample collection.
A full range of WatchGas reference (calibration) gases and sampling accessories: cylinders in sizes from 12 to 116 l (aluminium and steel), the low-adsorption, antistatic Last-O-More hose, ball floats (Ballfloat) protecting the hose from drawn-in liquid and dust, and a backpack for safe container sampling. Everything for bump testing, calibration and sample collection.
Note: The composition and concentration of the reference gas mixture are selected to match the sensor set. Cylinders have an expiry date.
Key features
- Reference gases: cylinders 12–116 l (aluminium and steel), various mixtures.
- Last-O-More hose — low adsorption, antistatic, accurate results.
- Ballfloat — a float protecting the hose from liquid and dust.
- Container sampling backpack — safe sample collection.
- For bump testing, calibration and sample collection.
- Compatible with WatchGas detectors and stations.
Technical specification
| Parameter | Value |
|---|---|
| Type | calibration gases + sampling accessories |
| Cylinders | 12 / 34 / 58 / 60 / 103 / 116 l (alu/steel) |
| Hose | Last-O-More (low adsorption, antistatic) |
| Sampling protection | Ballfloat (ball float) |
| Container sampling | backpack (Sampling Backpack) |
| Manufacturer | WatchGas |
Applications
Bump testing, calibration and sample collection for detectors — at the service base and in the field.
Frequently asked questions (FAQ)
Which gas cylinders are available?
From 12 to 116 l, aluminium and steel; we select the composition to match the detector's sensors.
What are the Ballfloat and Last-O-More hose for?
The Ballfloat protects the hose from drawn-in liquid/dust, and the Last-O-More ensures accurate results thanks to its low adsorption.
Brand and service
WatchGas — SafeTech is a distributor and service station: selection, delivery, configuration, calibration and servicing of WatchGas detectors and systems.
Why SafeTech
- 23 years of experience in gas detection (the company has operated since 2003).
- Authorised distributor and authorised service station.
- In-house service, calibration and certification in Suchy Dwór near Gdynia — service throughout Poland.
- Training and technical support (SafeTech Safety Academy).
Availability and service — Gdynia and the Tricity
WatchGas — calibration gases and sampling accessories — sales, selection, calibration and service in Gdynia (Suchy Dwór, on the border of Gdynia and the Kosakowo municipality). We serve the Tricity (Gdańsk, Sopot, Gdynia), Rumia, Reda, Wejherowo, the Pomorskie Voivodeship and all of Poland. Ask about pricing and availability.
Related products

Telescopic dielectric pike pole
non-conductive (up to 20,000 V)
View →
AGH1000B
portable sampling pump for gas detectors
View →
WatchGas
accessories and software (holsters, starters, simulator, Device Link, SST RTR)
View →