Home › Gas detectors and meters › Single-gas detectors › Dräger Pac 8000 — single-gas detector for special gases (incl. CO₂, Cl₂, NH₃, PH₃, O₃)
← Back to: Single-gas detectors
Dräger Pac 8000 — single-gas detector for special gases (incl. CO₂, Cl₂, NH₃, PH₃, O₃) — Single-gas detectors | SafeTech

Dräger Pac 8000 — single-gas detector for special gases (incl. CO₂, Cl₂, NH₃, PH₃, O₃)

The Dräger Pac 8000 is a rugged, reusable personal single-gas detector that detects hazardous concentrations of up to 29 different gases — including special gases such as nitrogen dioxide (NO₂), ozone (O₃) and phosgene (COCl₂) that standard detectors do not cover. Advanced sensors with a short t90 response time deliver instant reaction, and in addition to standard alarms you can define extra TLV and STEL thresholds. The shock- and chemical-resistant housing meets IP68 requirements.

The Dräger Pac 8000 is a rugged, reusable personal single-gas detector that detects harmful concentrations of as many as 29 different gases — including special gases such as nitrogen dioxide (NO₂), ozone (O₃) and phosgene (COCl₂) that standard detectors do not cover. Advanced sensors with a short t90 response time provide instant reaction, and in addition to the standard alarms you can define extra TLV and STEL thresholds. The housing, resistant to shocks and chemicals, meets IP68 requirements.

Note: The specific gas and its measuring range depend on the ordered sensor — one gas per unit, variant selected when ordering. The detector supports up to 29 gases in total.

Key features

  • Special-gas detection — incl. CO₂, Cl₂, NH₃, PH₃, O₃, NO, NO₂, HCN, organic vapors (OV/OV-A), phosgene.
  • Very high sensitivity — O₃ from as little as 0.02 ppm, phosgene (COCl₂) from 0.01 ppm, NO₂ from 0.04 ppm.
  • Configurable additional TLV and STEL alarm thresholds.
  • DrägerSensor XXS sensors with a short t90 response time.
  • 360° alarm signal (LED), audible and vibrating alarm.
  • Water- and dust-tight IP68; housing resistant to shocks and chemicals.
  • Time-stamped data logger; CC-Vision software.

Technical specifications

ParameterValue
Typesingle-gas, special gases (one gas per unit); up to 29 gases
Measured gasesincl. CO₂, Cl₂, HCN, NH₃, NO, NO₂, PH₃, O₃ (ozone), organic vapors (OV/OV-A), phosgene (COCl₂)
Ranges / alarm thresholdsCO₂ 0–5 %vol. (0.5/1) · Cl₂ 0–20 ppm (0.5/1) · HCN 0–50 ppm (1.9/3.8) · NH₃ 0–300 ppm (20/40) · NO 0–50 ppm (25/50) · NO₂ 0–50 ppm (5/10) · PH₃ 0–20 ppm (0.1/0.2) · OV/OV-A 0–200 ppm (10/20) · O₃ 0–10 ppm (0.1/0.2) · phosgene 0–10 ppm (0.1/0.2)
Detection sensitivityO₃ from 0.02 ppm · phosgene (COCl₂) from 0.01 ppm · NO₂ from 0.04 ppm
Additional thresholdsconfigurable TLV and STEL alarms
SensorDrägerSensor XXS, short t90 response time; membrane filter
Dimensions / weight64 × 84 × 20 mm (without clip) / approx. 106 g (113 g with clip)
Displaylarge, backlit; concentration and battery status
Alarmsaudible, visual (360° LED), vibrating
Protection ratingIP68; housing resistant to shocks and chemicals
Operating conditions−30…+55°C (selected sensors down to −40°C for max. 1 h); 700–1300 hPa; 10–90% RH non-condensing
Battery life2 years
Data loggingtime-stamped event logger; CC-Vision
CertificationscCSAus, IECEx, ATEX, CE
DockingDräger X-dock 5300 Pac; Bump Test station

Applications

Chemical and petrochemical industry, laboratories, water treatment (ozone, chlorine), refrigeration and logistics (NH₃, CO₂), emergency services and hazmat.

Frequently asked questions (FAQ)

Which special gases does the Pac 8000 detect?

Among others CO2, Cl2, HCN, NH3, NO, NO2, PH3, ozone (O3), organic vapors (OV/OV-A) and phosgene — up to 29 gases in total.

How sensitive is the Pac 8000?

It detects very low concentrations — ozone from as little as 0.02 ppm, phosgene from 0.01 ppm, NO2 from 0.04 ppm.

Does the Pac 8000 have additional alarm thresholds?

Yes — in addition to the standard alarms, you can define TLV and STEL thresholds.

Brand & service

Dräger — available from SafeTech together with expert selection, calibration and service.

Why SafeTech

  • 23 years of experience in gas detection (company operating since 2003).
  • Authorised distributor and service station (Honeywell, Bieler+Lang).
  • In-house service, calibration, certification and adjustment in Suchy Dwór near Gdynia — service throughout Poland.
  • Training and technical support (SafeTech Safety Academy).

Availability & service — Gdynia and Tricity

Dräger Pac 8000 — single-gas detector for special gases (incl. CO₂, Cl₂, NH₃, PH₃, O₃) — sales, selection, calibration and service in Gdynia (Suchy Dwór, on the border of Gdynia and the Kosakowo municipality). We serve the Tricity area (Gdańsk, Sopot, Gdynia), Rumia, Reda, Wejherowo, the Pomerania region and all of Poland. Ask about our offer and availability.

Accessories and compatible equipment

  • Calibration & bump test: stacja Dräger X-dock, calibration gas mixtures, regulators and pressure-reducing valves for cylinders.
  • Sensors & filters: replacement sensors matched to the measured gas, dust and hydrophobic filters.
  • Sampling: probe, hose, aspirator bulb (for diffusion versions).
  • Carrying & protection: lanyard, clip, holder, transport case, charger/power supply.
Sampling pumps available in our range:

Full selection of accessories and parts for this model — request a quote.