Dräger X-am® 5100 — single-gas detector for reactive gases (HF, HCl, H₂O₂, hydrazine)
The Dräger X-am 5100 is a specialized single-gas detector for safe work with reactive gases: hydrogen fluoride (HF), hydrogen chloride (HCl), hydrogen peroxide (H₂O₂) and hydrazine. It uses a sensor tailored to the specifics of reactive gases and a design that gives gas direct access to the sensor, delivering a fast, reliable response where standard detectors have limitations.
The Dräger X-am 5100 is a specialist single-gas detector for safe work with reactive gases: hydrogen fluoride (HF), hydrogen chloride (HCl), hydrogen peroxide (H₂O₂) and hydrazine. It uses a sensor tailored to the characteristics of reactive gases and a design ensuring direct gas access to the sensor, which translates into a fast and reliable response where standard detectors have limitations.
Note: The X-am 5100 is a single-gas detector specialized in reactive gases (HF, HCl, H₂O₂, hydrazine), which are difficult to detect with standard sensors.
Key features
- Detection of reactive gases: HF, HCl, H₂O₂ and hydrazine.
- Sensor tailored to the characteristics of reactive gases.
- Design ensuring direct gas access to the sensor.
- Fast, reliable response to gases that are difficult to detect by standard means.
- Robust enclosure for work in harsh conditions.
- Compatible with the X-dock station (testing and calibration).
Technical specifications
| Parameter | Value |
|---|---|
| Type | single-gas detector for reactive gases |
| Measured gases | HF, HCl, H₂O₂, hydrazine |
| Sensor | tailored to reactive gases; direct gas access |
| Protection rating | IP54 |
| Alarms | visual, audible, vibrating |
| Dimensions / weight | 130 × 48 × 44 mm |
| Approvals | ATEX (detailed markings per manufacturer datasheet) |
| Docking | X-dock station (testing and calibration) |
Applications
The chemical and semiconductor industries, laboratories, processes involving HF/HCl/H₂O₂, rescue services.
Frequently asked questions (FAQ)
What gases does the Dräger X-am 5100 detect?
Reactive gases: hydrogen fluoride (HF), hydrogen chloride (HCl), hydrogen peroxide (H₂O₂) and hydrazine.
Why is a special detector needed for these gases?
Reactive gases are difficult to detect with standard sensors. The X-am 5100 has a sensor tailored to their characteristics and a design ensuring direct gas access to the sensor.
Is the X-am 5100 a single- or multi-gas detector?
It is a single-gas detector, specialized in reactive gases.
Brand & service
Dräger — available from SafeTech together with expert sensor configuration selection, calibration and service.
Why SafeTech
- 23 years of experience in gas detection (in business since 2003).
- Distribution and support for the Dräger brand; sensor configuration selection for your application.
- In-house service, calibration, certification and adjustment in Suchy Dwór near Gdynia — service across Poland.
- Training and technical support (SafeTech Safety Academy).
Availability & service — Gdynia and Tricity
Dräger X-am® 5100 — single-gas detector for reactive gases (HF, HCl, H₂O₂, hydrazine) — sales, selection, calibration and service in Gdynia (Suchy Dwór, on the border of Gdynia and the Kosakowo municipality). We serve the Tricity (Gdańsk, Sopot, Gdynia), Rumia, Reda, Wejherowo, the Pomerania region and all of Poland. Ask about a quote and availability.
Accessories and compatible equipment
- Calibration & bump test: stacja Dräger X-dock, calibration gas mixtures, regulators and pressure-reducing valves for cylinders.
- Sensors & filters: replacement sensors matched to the measured gas, dust and hydrophobic filters.
- Sampling: probe, hose, aspirator bulb (for diffusion versions).
- Carrying & protection: lanyard, clip, holder, transport case, charger/power supply.
Full selection of accessories and parts for this model — request a quote.