HomeDetektory prądu i monitory skażeńRadiological contamination monitorsEKO-C1 radioactive contamination meter — alpha/beta/gamma radiometer
← Back to: Radiological contamination monitors
EKO-C1 radioactive contamination meter — alpha/beta/gamma radiometer — Radiological contamination monitors | SafeTech

EKO-C1 radioactive contamination meter — alpha/beta/gamma radiometer

The EKO-C1 is a portable meter (radiometer) for radioactive contamination with two detectors: a Geiger-Müller counter and a scintillation (alpha) detector. It measures alpha and beta surface contamination and the dose rate from X-ray and gamma sources. It performs well in isotope laboratories, at border crossings and in areas following nuclear and transport accidents — wherever contamination must be detected and assessed quickly.

The EKO-C1 is a portable meter (radiometer) for radioactive contamination with two detectors: a Geiger-Müller counter and a scintillation (alpha) detector. It measures alpha and beta surface contamination and the dose rate from X-ray and gamma sources. It performs well in isotope laboratories, at border crossings and in areas following nuclear and transport accidents — wherever contamination must be detected and assessed quickly.

Note: Configuration selection and calibration depend on the application. The device requires periodic metrological inspection.

Key features

  • Two detectors: a Geiger-Müller counter + a scintillation (alpha) detector.
  • Measurement of alpha and beta contamination and the dose rate of X-ray and gamma sources.
  • Energy range: X/gamma 30 keV–1.5 MeV; beta > 500 keV; alpha > 4 MeV.
  • Surface-contamination and dose-rate measurement in one device.
  • For laboratories, border crossings and post-accident areas.

Technical specification

ParameterValue
Typeportable radioactive-contamination radiometer
DetectorsGeiger-Müller + scintillation (alpha)
Dose rate0.01–999.9 µSv/h
Surface contamination0.1–9999 Bq/cm²
Pulse rate0.1–9999 cps
Energy rangeX/gamma 30 keV–1.5 MeV; beta >500 keV; alpha >4 MeV

Applications

Detection and measurement of alpha/beta/gamma contamination and dose rate — rescue services, fire service, laboratories, CBRN.

Frequently asked questions (FAQ)

What does the EKO-C1 measure?

Alpha and beta surface contamination and the dose rate of X-ray and gamma radiation — thanks to its two detectors (G-M and scintillation).

Where is it used?

In isotope laboratories, at border crossings and in areas following nuclear or transport accidents.

Brand and service

SafeTech — SafeTech (Suchy Dwór near Gdynia) — selection, supply, training and service; nationwide coverage in Poland.

Why SafeTech

  • 23 years of experience in fire-service and rescue equipment (in business since 2003).
  • Authorised distributor and service station for safety equipment.
  • Product selection, supply and technical support across Poland — headquarters in Suchy Dwór near Gdynia.
  • Training and consultancy (SafeTech Safety Academy).

Availability and service — Gdynia and the Tricity

EKO-C1 radioactive contamination meter — alpha/beta/gamma radiometer — sales, selection, calibration and service in Gdynia (Suchy Dwór, on the border of Gdynia and the Kosakowo municipality). We serve the Tricity (Gdańsk, Sopot, Gdynia), Rumia, Reda, Wejherowo, the Pomeranian Voivodeship and all of Poland. Ask about pricing and availability.

Type at least 2 characters — e.g. x-am, Dräger