Gas detection3
Respiratory protection4
Technical rescue9
Firefighting4
Safety & environment4
Personal protective equipment2

Dräger RZ 7000 — portable tester for closed-circuit breathing apparatus (CCBA)
The Dräger RZ 7000 is a portable device for functional and leak tests of Dräger PSS BG4 plus and Dräger BG ProAir closed-circuit breathing apparatus (CCBA). Once switched on, it automatically zeroes the sensor and is ready to work, and a built-in hand pump generates both positive and negative pressure without any additional accessories. A compact, rugged IP54 housing and a lithium-ion battery (min. 24 h of operation) let you test equipment both in the ODO workshop and in the field.
Key features
- Fast and easy functional and leak tests for Dräger PSS BG4 plus and Dräger BG ProAir closed-circuit breathing apparatus (CCBA).
- Automatic sensor zeroing after switch-on — the device is ready to work immediately.
- A self-locking adapter ensures a secure connection to the apparatus throughout the test.
- Built-in hand pump (aluminium handle, stainless-steel shaft) — generates positive pressure immediately, and negative pressure after a single turn of the switch, with no additional switching needed.
- Five-position switch — selects the pump direction, flow measurement (automatic switch to the flow sensor) and rapid venting without disconnecting the apparatus.
- Backlit display shows the current pressure as well as the stored start and end values of the test; during the leak test a timer counts down the remaining time and calculates the pressure difference.
- Portable, rugged housing rated IP54 (with the cover closed), resistant to dust and splashing water.
- Lithium-ion battery — min. 24 h of operation without external power, configurable auto-shutdown, and can run while charging.
- Optional Dräger Protector Software documents the results and automatically tracks the dates of subsequent tests, with reports printed immediately or later.
- An optional test head extends testing to full-face masks with an RP connector.
Technical specifications
| Parameter | Value |
|---|---|
| Type | portable test device for closed-circuit breathing apparatus (CCBA) — functional and leak tests |
| Equipment tested | Dräger PSS BG4 plus, Dräger BG ProAir; optionally full-face masks with an RP connector (test head) |
| Pressure measurement range | 30 mbar to -30 mbar, accuracy ±1% of the final value |
| Volumetric flow measurement range | 0.5–4 l/min, accuracy 5% of the measured value |
| Internal test volume | 500 ml |
| Power supply | 100–240 V (50–60 Hz); optional 12 V car charger |
| Battery | lithium-ion — min. 24 h of operation without external power |
| Protection rating | IP54 (with the cover closed) |
| Weight | 8.3 kg (with power supply, excluding operating manual) |
| Dimensions (W × H × D) | 470 × 357 × 176 mm |
| Scope of delivery | mains power supply, operating manual |
| Calibration interval | 24 months (subject to national regulations) |
| Part number | R62500 |
| Manufacturer | Dräger |
Applications
Respiratory-protection service stations, fire brigades and industrial plants using Dräger PSS BG4 plus or BG ProAir closed-circuit breathing apparatus (CCBA) — periodic functional and leak checks, both in the workshop and directly in the field thanks to the portable design.
Frequently asked questions (FAQ)
What breathing apparatus does the RZ 7000 test?
The RZ 7000 is used for functional and leak tests of Dräger PSS BG4 plus and Dräger BG ProAir closed-circuit breathing apparatus (CCBA). With the optional test head it can also test full-face masks with an RP connector.
Can the device be used outside the workshop?
Yes — it is a portable device in a compact, rugged IP54-rated housing, powered by a lithium-ion battery sufficient for min. 24 h of operation without external power; it can also run while charging.
How often does the RZ 7000 need to be calibrated?
The standard calibration interval is 24 months, subject to applicable national regulations.
Can the test results be documented?
Yes — the optional Dräger Protector Software saves the test results and automatically tracks the dates of subsequent tests; reports can be printed immediately or generated later.
Brand & service
The equipment and implementation are in the SafeTech range — selection, delivery, commissioning and service of the portable test device for CCBA closed-circuit breathing apparatus. We also provide periodic servicing and calibration as part of comprehensive care for the respiratory-protection workshop.
Why SafeTech
- 23 years of experience equipping fire services and industry (the company has operated since 2003).
- In-house respiratory-protection service station: cleaning, drying, testing and maintenance of breathing apparatus and masks.
- Service, inspections, pressure tests and certification in Suchy Dwór near Gdynia — service across Poland.
- Training and technical support (SafeTech Safety Academy).
Availability & service — Gdynia and Tricity
Dräger RZ 7000 — portable tester for closed-circuit breathing apparatus (CCBA) — sales, selection, delivery and service in Gdynia (Suchy Dwór, on the border of Gdynia and the Kosakowo municipality). We serve the Tricity (Gdańsk, Sopot, Gdynia), Rumia, Reda, Wejherowo, the Pomerania region and all of Poland. Ask about pricing and availability.